ECONAR® Energy Systems - Commercial
Case Study
City of Ramsey Police Department - Ramsey, Minnesota
With a projected operating cost of $4,900 for a conventional
heating system, and a GeoSource operation cost of $2,968 the system payback
was just over three years. It was an easy decision to use the ECONAR GeoSource
System. This is one of the many buildings built by Sharp Construction
using the ECONAR GeoSource System.
Geo$ense
Total installed price for the HVAC system was $49,700. This
included two GH670-2-T000 (6Ton), two GH590-2-T000 (5 Ton), and 4000 CFM
energy recovery ventilator for fresh air venting of restrooms.
Physical Data
10,418 square feet
22 600 foot slinky loops in fields of 10 and 12 each
Loop Field area of 88 feet by 80 feet
1.5 Horsepower power pump for circulation
General Contractor Sharp Construction, Champlin, MN