ECONAR® Energy Systems - Earth Loop
Field
Wesley Homes Vertical Loop
Physical Data
Wesley Homes, a premier home builder in the greater Metropolitan
area of Minneapolis and St. Paul, has incorporated ECONAR GeoSource Heat
Pumps into many of his new homes. This home, in an upper end development
and with yard area at a premium, utilizes a vertical earth loop. The vertical loop system consists
of 10 holes and bored to a depth of 96 feet each and spaced 10 feet apart.
A high density PE3408 plastic pipe is inserted into every hole, connected
at the bottom with a u-bend. All underground connections are fusion welded
by the certified loop installer. The holes are then sealed using a bentonite
grout and piped together to a common manifold that runs into the building
below the frost line. The fluid that flows through the vertical loop system
is a combination of water and food grade antifreeze. The system has an
expected design life of 200 years and carries a 50-year warranty on the
pipe from the manufacturer.